MUNICH - SEVERAL RESIDENTIAL BUILDINGS ELASTICALLY DECOUPLED WITH CIBATUR® AND CIMAX®


The project includes two single-family houses, one semi-detached house and two structures containing apartments, which are close to a railway line. The vibration and secondary airborne noise immissions caused by railway traffic exceeded the limits of a technical guideline, therefore protective measures are needed. With dynamics expert ‘s analysis, clients were offered economical and technical efficient solutions that ensured living in residential comfort.

[image_l=297#5,297]Single-family houses in Gräfelfing: In the first house near the railway line, Cibatur® was installed in two layers and in the second house in one layer under the foundation. Civerso A was mounted doubled layed at front outer basement wall (facing the railway line) and single layed on the flank sides.
Semi-detached house in Gröbenzell: The basement of the house is located beneath groundwater level. Since the dynamic immission was not very intensive, Cimax® strip-layer as one layer was installed under its foudation. The intermediate areas were filled with two layers of Civerso A.
Residential buildings with basement in Bauseweinallee: In the area close to railway line, Cibatur® was used in two layers under the foundation and in the rest area in one-layer Cibatur® and Civerso A in different thickness were installed at the outer basement wall, depending on the immission intensity and earth pressure.